  Abstract: In this paper, monitoring of some parameters in wastewater from domestic wastewater treatment plant is evaluated. The wastewater from the selected plant is characterized by COD, BOD5, pH, TSS. The wastewater samples were collected from the
Share
Transcript
  International OPEN ACCESS Journal   Of Modern Engineering Research (IJMER) | IJMER | ISSN: 2249 – 6645 | www.ijmer.com | Vol. 4 | Iss. 5| May. 2014 | 67 | Monthly Monitoring Of Some Physico- Chemical Parameters İn Domestic Wastewater Treatment Plant İn Turkey: A Case Study On Selected Plant Serpil SAVCI 1 , Ayça DURAK  2   1, 2 (Bozok University Engineering Arthitecture Faculty, 66100, Yozgat, Turkey) I.   Introduction Over the last century, environmental problems related to human activities have increased as a consequence of population growth. Pollution of water resouces has become a major concern for environmental monitoring physical, chemical and bacteriological parameters associated to water quality. In this context, wastewater treatment plants play an important role as human activity closely associated with sustainable. Activated sludge treatment has been used worldwide in secondary treatment systems. The wastewater  purification performance of activated sludge treatment depends heavily on the metabolism with bacteria playing a key role in the purification process. Sewage water is a complex matrix. These include high concentration of BOD, COD, high dissolved solid. Traditionally, the quality of treated wastewater is defined by the measurement of parameters such as chemical oxigen demand (COD), biological oxigen demand (BOD), nitrate, sulphate, etc. These parameters  provide crucial information on the quality of the influent, effluent wastewater and performance of treatment  plants [1]. Previous studies, on domestic sewage treatment systems have mainly focused on removal of chemical oxygen demand, biochemical oxygen demand, total suspanded solid and nitrogen [2]. Information about the monitoring of these in domestic treatment systems is limited. Yozgat is a city in Turkey. The city is located at an elevation of 4380 ft (1,335 m), situated 170 km east of Ankara, near the head of a narrow valley through which the Ankara-Sivas road runs. According to 2009 census, population of the district is approximately 113,614 of which 73,835 live in the city of Yozgat. The main industries in Yozgat are textiles, food, cement, manufacturing and metallurgy [3-13]. According to national standards (Table 1), the receiving the water standards are based on organik load/  population equivalency [4]. The standards cover four main parameters without considering the bacteriological status. Table 1.Discharge standards of domestic wastewater to receiving waters in Turkey [11]. Parameter Composite sample (2h), Pop. 1000-10000 Composite sample (24h), Pop.1000-10000 Composite sample (2h), Pop>100000 Composite sample (24h), Pop. >100000 BOD 5 mg/L 50 45 40 35 COD mg/L 160 110 120 90 TSS mg/L 60 30 40 25  pH 6-9 6-9 6-9 6-9 Abstract:  In this paper, monitoring of some parameters in wastewater from domestic wastewater treatment plant is evaluated. The wastewater from the selected plant is characterized by COD, BOD 5  ,  pH, TSS. The wastewater samples were collected from the inlet and outlet to monthly from a wastewater treatment plant to the city of Yozgat in Turkey for eight months from May 2013 to  December 2013. Results of a detailed survey on the performance of a selected plant was given both in terms of influent and effluent quality and in comparision with the current legislation on discharge limits to receiving waters. The results of effluent showed that the values of these parameters are ranged on average between 16,7 and 27,2 mg/L for biological oxygen demand (BOD 5  ), between 22,3 and 36,2 mg/L for chemical oxigen demand and between <10 and 21 total suspanded solid. All these values are beyond World Health Organization and Turkish Standards recommendations for wastewater discharge. Keywords:     sewage, monitoring,WHO, Turkey.     Monthly monitoring of some physico-chemical parameters in domestic wastewater treatment plant in | IJMER | ISSN: 2249 – 6645 | www.ijmer.com | Vol. 4 | Iss. 5| May. 2014 | 68 | In this study, wastewater samples (influent and effluent) were collected monthly from WWTP in Turkey for 8 months from May 2013 to December 2013. Typical pollution parameters measured in wastewater treatments  plants such as chemical oxigen demand (COD), biological oxigen demand (BOD 5 ), pH and total suspanded solids. II.   Materials and methods 2.1. Waste water treatment plant operation Wastewaters in WWTP are treated by mechanical-biological method by using active sludge. In order to maintain quality raw and treated wastewater, the quality of activated sludge and optimal operating conditions, and the operation of wastewater treatment plant are daily monitored. Measurements of different physical quantities such as temperature, flow, redox potential, pH of water and conductance are performed daily bu using standard laboratory equipment, instrument Sesinon (model 51935-00). Before and after treatment, the composition and quality of wastewater are determined daily by using standard analytical methods [5]. 2.2. Water Samples Water samples used in this study were collected from the effluents of secondary sedimantation in a WWTP. The WWTP has a treatment capacity of 26.000 m 3 /d, serving a community in the middle of Turkey. The basic treatment process of the WWTP is primary sedimentation, followed by an anaerobic  –  anoxic  –  oxic process as its secondary treatment. Eight groups of samples were collected from May 2013 to December 2013. The water samples were transported to laboratory on ice, stored at 4 °C and analyzed on the day of collection. 2.2. Analysis of waste water The study was conducted sewage treatment plant Yozgat in Turkey. Samples were collected from the influent and effluent waste water at biological wastewater treatment plant. Samples were collected in first week of every month during the year 2013 from May to December. Samples were collected in glass containers, pre-cleaned by washing with non-ionic detergents, rinsed with tap water, 1:1 hydrochloric acid and finally with deionised water. Before sampling, the bottles were rinsed three times with sample water pH, temperature, BOD 5 , COD and TSS were analyzed according to the methods prescribed by the APHA [5]. III.   Result and Discussion The wastewater quality analysis of influent of sewage treatment plant has been carried out for physico-chemical parameters like, pH, COD, BOD 5  and TSS. The results are given in Table 2. Table 2. Physicochemical parameters of influent of sewage treatment plant Parameters/ Months May June July Au Sep Oc Nov Dec  pH 8.82 8.50 8.63 8.52 8.54 8.58 8.52 8.55 COD 810 680 630 777 806 791 820 840 BOD 5 607 510 472,5 583 604 593 615 630 TSS 198 212 161 205 228 178,5 185,5 192,2 The wastewater quality analysis of effluent of sewage treatment plant has been carried out for physico-chemical  parameters like, pH, COD, BOD 5  and TSS. The results are given in Table 3. Table 3. Physicochemical parameters of effluent of sewage treatment plant Parameters/ Months May June July Au Sep Oc Nov Dec  pH 7,70 7,20 7,60 7,70 7,80 7,70 7,90 7,90 COD 33,2 28,6 35,4 26,7 22,3 27,1 33,4 36,2 BOD 5 25 22 26,5 20 16,7 20 25 27,2 TSS 11 <10 15 <10 <10 11 18 21 Temperature also measured in WWTP. It usually depends on the season, geographic location and sampling time. During the period of investigation temperature values in beetwen 13.5 to 20.6 0 C. The minimum value was observed in month of December and the maximum value was observed in month of May. The variation in the water temperature may be due to different timings of collection and influence of season.   Monthly monitoring of some physico-chemical parameters in domestic wastewater treatment plant in | IJMER | ISSN: 2249 – 6645 | www.ijmer.com | Vol. 4 | Iss. 5| May. 2014 | 69 | 3.1 Chemical Oxigen Demand The mean COD in the untreated wastewater was from 630 to 840 mg/L (Table 2 ). There was strong variation in COD concentrations over the sampling period. The minimum value was observed in the month of July while the maximum value was observed in the month of December in the influent of biological waste water plant in Yozgat in Turkey. The COD of the treatment wastewater is low in comparision to the range of COD values reported in the literature for domestic wastewater; including representative concentrations reported by Metcalf&Eddy Inc. (1991) of 250 mg/L, 430 mg/L and 800 mg/L for weak, medium and strong wastewater, respectively [6]. Chemical Oxigen Demand 0100200300400500600700800900May June July Aug Sept Oct Nov Dec     m    g      /      L  Figure 1. Variation of COD in Influent of WWTP Chemical Oxigen Demand 0510152025303540May June July Aug Sept Oct Nov Dec     m    g      /      L  Figure 2. Variation of COD in Effluent of WWTP 3.2 Biological Oxigen Demand In the present study, BOD 5  varied from 16,7 mg/L to 27,2 mg/L in the effluent of domestic waste water treatment plant. The minimum value was observed in the month of September while maximum value was observed in the month of December. BOD 5  indicates the present of microbial activities and dead organic matter. BOD 5  is directly linked with decomposition of dead organic matter present in the wastewater and hence the higher values of BOD 5  can be directly related with pollution status of the wastewater. The higher values of BOD 5  means present of more biodegradable organic matter [9-10]. 5-Day BOD 0100200300400500600700May June July Aug Sept Oct Nov Dec     m    g      /      L  Figure 3. Variation of BOD 5  in Influent of WWTP   Monthly monitoring of some physico-chemical parameters in domestic wastewater treatment plant in | IJMER | ISSN: 2249 – 6645 | www.ijmer.com | Vol. 4 | Iss. 5| May. 2014 | 70 | 5-Day BOD 051015202530May June July Aug Sept Oct Nov Dec     m    g     /     L  Figure 4.Variation of BOD 5  in Effluent of WWTP Total Suspanded Solids The concentration of suspanded solids (TSS) in the untreted sewage was 161±212 mg/L, whereas from treated effluent varied from <10-21 mg/L respectively. Figure 5-6 shows the variation of suspanded solids from the inlet and outlet of wastewater treatment plant. The values shows suspanded solids are in permissible limit as compared with Turkish Standards [12]. Suspanded Solids 050100150200250May June July Aug Sept Oct Nov Dec     m    g     /     L  Figure 5. Variation of Suspanded Solids in Influent of WWTP Suspanded Solids 0510152025May June July Aug Sept Oct Nov Dec     m    g     /     L  Figure 6. Variation of Suspanded Solids in Effluent of WWTP   Monthly monitoring of some physico-chemical parameters in domestic wastewater treatment plant in | IJMER | ISSN: 2249 – 6645 | www.ijmer.com | Vol. 4 | Iss. 5| May. 2014 | 71 | Water pH  pH measurements are common in wastewater treatment plant. The pH of the raw sewage was 8.52-8.82 and the system reduced the pH to values close to 7.20-7.90. These results are consistent with the behavior of pH in other treatment plants. There was no significant difference. WHO recommended maximum pemissible limit of pH from 6.5 to 9.2 [7-8]. pH value of different samples is within the desirable and suitable range. Figure 7-8 shows the variation of suspanded solids from the inlet and outlet of wastewater treatment plant pH 8,38,48,58,68,78,88,9May June July Aug Sept Oct Nov Dec  Figure 7. Variation of pH in Influent of WWTP pH 6,877,27,47,67,88May June July Aug Sept Oct Nov Dec  Figure 8. Variation of pH in Effluent of WWTP IV.   Conclusion This study evaluated the physico-chemical properties rather than bacteriological parameters of a domestic wastewater treatment plant in Turkey. The physico-chemical characteristics of effluent is light brown in colour, pH shows alkaline nature of the effluent, TSS, BOD 5 , COD are the parameters from the treated effluent is low in concentrations compared to Turkish standars. The concentration of the investigated in the water samples from Yozgat/Turkey were found below the guidelines for waste water given by WHO. The study showed a need for a continuous pollution monitory program. REFERENCES [1.]   LOOS, R., CARVALHO, R., ANTÓNIO, D. C., COMERO, S., LOCORO, G., TAVAZZI, S., PARACCHINI, B., GHIANI, M., LETTIERI, T., BLAHA, L., JAROSOVA, B., VOORSPOELS, S., SERVAES, K., HAGLUND, P., FICK, J., LINDBERG, R. H. EU-wide monitoring survey on emerging polar organic contaminants in wastewater treatment plant effluents. Water Research, 47:17:6475-6487, 2013. [2.]   H. LIANG, M. GAO, J. LIU, Y. WEI, X. GUO. A novel integrated step-feed biofilm process for the treatment of decentralized domestic wastewater in rural areas of China. J Environ Sci, 22 (3) pp. 321  –  327, 2010. [3.]   SAVCI, S., BELLITURK, K. Assesment of Irrigation Water Quality of Some Provinces of Turkey. International Journal of Modern Engineering Research, 3:1 pp:19-22, 2013.
Related Search
Similar documents
View more
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks
SAVE OUR EARTH

We need your sign to support Project to invent "SMART AND CONTROLLABLE REFLECTIVE BALLOONS" to cover the Sun and Save Our Earth.

More details...

Sign Now!

We are very appreciated for your Prompt Action!

x